ACTA MEDICA
ACTA MEDICA
Acta Medica (Hradec Králové) je víceoborový vědecký recenzovaný časopis vycházející v angličtině. Acta Medica publikují review, původní články, stručná sdělení, případové studie a oznámení. Časopis byl založen v roce 1958 pod názvem Sborník vědeckých prací Lékařské fakulty Univerzity Karlovy v Hradci Králové. Je indexován v databázích Chemical Abstracts, CNKI, DOAJ, EBSCO, Hinari, Index Medicus, MEDLINE, Scopus a Ulrichsweb.

ACTA MEDICA, Vol 66 No 3 (2023), 107–111

Comparison of Short and Long-Term Results after Injection Laryngoplasty with Radiesse® Voice and Thyroplasty Type I in Unilateral Vocal Fold Palsy

Katarína Smatanová, András Burián, Jakub Dršata, Jana Krtičková, Anikó Kőnig-Péter, Jan Mejzlík, Viktor Chrobok

DOI: https://doi.org/10.14712/18059694.2024.2
zveřejněno: 21. 03. 2024

Abstract

Objectives: Unilateral vocal fold palsy independently of etiology results in glottic insufficiency leading to unfavorable short or long-term impact on voice quality. Our aim was to evaluate the effect of injection laryngoplasty using Radiesse® Voice and thyroplasty type I on glottic closure, voice quality and aerodynamics by comparing preoperative, short- and long-term results. Materials and Methods: Data of 32 consent patients were reviewed between 2012 and 2023. All patients underwent either injection laryngoplasty (14 patients) or thyroplasty type I (18 patients) under local anesthesia. Maximum phonation time, glottic closure based on videolaryngostroboscopy, VHI-30 values and GRBAS scale were recorded prior, short-term (3 month) and long-term (12 months) after procedures for statistical comparison. Friedman test, Mann-Whitney test and Wilcoxon signed rank tests were used for statistical analysis. Results: In injection laryngoplasty group, we found significant improvement in maximum phonation time (p = 0.002), grade of hoarseness (p = 0.002) and breathiness (p = 0.000) when comparing results before and short-term after procedure. In thyroplasty type I group we saw significant improvement of maximum phonation time (p = 0.000), glottic insufficiency (p = 0.000), all three VHI-30 components (p = 0.000), as well as grade of hoarseness, breathiness (both p = 0.000) and roughness (p = 0.011) of GRBAS scale when comparing voice outcome before and short-term after procedure. There was no significant difference in voice outcome results neither between short and long-term results nor between the two groups in any parameter. Conclusion: These results demonstrate both short and long-term efficiency of injection laryngoplasty and thyroplasty type I in the improvement of voice quality and glottic closure.

klíčová slova: glottic closure; injection laryngoplasty; thyroplasty type I; unilateral vocal fold palsy; voice quality

Creative Commons License
Comparison of Short and Long-Term Results after Injection Laryngoplasty with Radiesse® Voice and Thyroplasty Type I in Unilateral Vocal Fold Palsy is licensed under a Creative Commons Attribution 4.0 International License.

210 x 297 mm
vychází: 4 x ročně
cena tištěného čísla: 150 Kč
ISSN: 1211-4286
E-ISSN: 1805-9694

Ke stažení